Prove a feedstock stream once.
FEED tests a feedstock supplier’s streamA feedstock supplier’s recurring source of one feedstock, such as a sawmill’s bark or a utility’s biosolids. against four gates. The stream comes out carrying an evidence package, gate findings, and a carbon profile that every buyer, registryAn organization that sets the rules for carbon credits and issues them, such as Isometric or Puro.earth., and verifierAn independent auditor, hired by the CDR developer or biofuel producer, that checks the evidence behind a credit or claim. can use.
FEED is a feedstockThe raw material a plant runs on, such as wood residues, manure, biosolids, or crushed rock. standard. It sets what has to be true about a residual stream before that stream can be sold into carbon removalTaking carbon dioxide out of the atmosphere and storing it for a long time, such as underground or in biochar. or biofuelFuel made from organic feedstock, such as renewable diesel, biodiesel, sustainable aviation fuel, renewable natural gas, and ethanol., and what evidence has to exist to show it. Registries and fuel programs each ask their own version of these questions. FEED answers all of them once, at the feedstock supplier, to the strictest depth any of them sets.
Three things travel with the designated stream
Evidence package.
Every record behind the designation, compiled once and mapped to each registry and program the stream is sold under, at the strictest depth any of them sets. Mapped today to Isometric and Puro.earth.
Gate findings.
What each gate found for this stream: that it is genuinely residual, where it went before the sale and how long its carbon would have lasted, which requirements it cleared, and whether the sale causes market leakageEmissions that move elsewhere because of a purchase, when a displaced user replaces the feedstock with something else or a feedstock supplier produces more.. Annual monitoring keeps them current.
Carbon profile.
Feedstock emissions and carbon content from origin to pickup, built on GREET LCAAn accounting of all the emissions from making a product, from raw material to finished product. models. It is not a CIThe greenhouse gas emissions behind a fuel over its life cycle, per unit of energy. score. Delivery emissions are added only through the FEEDstock Desk.
The Designated QuantityThe share of a feedstock supplier’s stream that clears every gate and can be sold, in dry metric tons for a given reporting period. It carries the evidence package, gate findings, and carbon profile with it. The rest of the stream is excluded, each ton with its reason recorded. itself is the whole stream less every quantity excluded at any gate, in dry metric tons, computed for each reporting period. Each quantity is excluded once, at the first gate where it fails.
FEED designation summaryBiosolidsWastewater utility
Designated Quantity: 31,000 dry metric tons of a 40,000 dry metric ton stream
Exclusions
- 6,000 dry metric tons excluded at Gate 2, land applied on nearby farms as fertilizer, a productive use in the disposition record
- 3,000 dry metric tons excluded at Gate 4, displacement leakage, a cement plant in the supply shed has contracted that share as kiln fuel starting next year
Gate findings
- Gate 1: residual, a by-product of wastewater treatment
- Gate 2: disposition records show landfill disposal for the designated share
- Gate 3: all fourteen universal requirements cleared
- Gate 4: no supply, displacement, or land-use leakage in the Designated Quantity
Carbon profile
Carbon content and feedstock emissions from origin to pickup, calculated for this stream.
Mapped to
Isometric · Puro.earth
Four gates, two exclusions, one Designated Quantity
Hover or tap any element. Gates 1 through 3 run on evidence. Gate 4 runs on analysis.
- Residual feedstock streams enter FEED from a source facility, a land unit, or an aggregated unit.
- Gate 1, Waste origin, tests generation character. A quantity that fails is excluded to E.
- Gate 2, Counterfactual and durability, tests disposition history and durability. A quantity that fails is excluded to E. An excluded quantity can return to Gate 2 through the cure route once the missing evidence is supplied.
- At the disposition split, historic disposition evidence places each fraction in a disposition category: A, disposal; A-CDR, CDR procurement; C, productive use; or C-BIO, biofuel. A fraction with no records is excluded to E.
- Unproductive use evidence moves a fraction from C to B, unproductive use. The rest of C is excluded to E.
- In a FEED CDR designation, C-BIO is excluded to E. In a FEED Biofuel designation, C-BIO continues to Gate 3.
- A, A-CDR, and B continue to Gate 3, Eligible waste, which tests universal requirements 1 to 14. A quantity that fails is excluded to E.
- Gate 4, Market leakage, runs the payment, baseline, and regional screens, then tests supply leakage, displacement leakage, and land-use leakage. A quantity that fails is excluded to E-ML.
- What clears Gate 4 is the FEED Designated Quantity. A quantity in E-ML can rejoin it through the cure route once the leakage condition no longer holds.
- The FEED Designated Quantity carries three outputs: the evidence package, the gate findings, and the carbon profile.
The gates divide the work by what can actually be tested
Gates 1 through 3 test what the stream is, and they run on the feedstock supplier’s own records. Gate 4 tests what the sale does, and it cannot run on those records at all, because the question is what happens in the market around the supplier rather than inside it.
That is the part of FEED that cannot be assembled from documents. Gate 4 runs on a supply shedThe area a feedstock can be hauled from at reasonable cost, and the feedstock suppliers and buyers in it. analysis of feedstock supply, competing users, and demand in the region a stream is drawn from, built on the residual feedstock supply shed data Ecostrat has been compiling across North America for decades. Without that data the leakage questions can only be answered by proxy, which is why registries otherwise fall back on limits on what a CDR developer is allowed to pay.
One stream, one feedstock supplier, one designation
A FEED designation covers a single stream from a single feedstock supplier. A second stream, or a second feedstock supplier, is a separate designation. Feedstock suppliers apply for their own stream. CDR developers and biofuel producers put forward one feedstock supplier they buy from, or plan to buy from. The designation that results travels with the feedstock to whoever buys it, and to the verifier and the registry or program behind the sale.
A stream can be designated FEED CDR for carbon removal, FEED Biofuel for biofuel, or both. The scope is declared at the time of designation.
Every finding is recomputable
Each finding is tied directly to the evidence behind it, so a verifier can independently reach the conclusion the designation states rather than taking it on trust. A verifier, buyer, or program auditor finds every feedstock record it needs in the evidence package and never has to go back to the feedstock supplier.
Prospective buyers see the gate findings, the Designated Quantity, and the carbon profile. The feedstock supplier’s commercial data is redacted. The full evidence package goes to a buyer under contract, the buyer’s verifier, and the registry or program the buyer reports under.
Who stands behind a designation
Ecostrat designates feedstock and, through the FEEDstock Desk, will also buy and sell it. A designation does not rest on Ecostrat’s word. The buyer’s verifier can recompute every finding from the evidence, and the registry or program makes the final decision. The FEED standard is under review by a technical committee and will be published in 2027.
What a free FEED designation includes
A free FEED designation covers one feedstock stream from one feedstock supplier.
The designated stream comes with:
- An evidence package mapped to the feedstock rules of each registry and program the stream is sold under.
- Gate findings that a verifier can recompute.
- A carbon profile of the stream from origin to pickup.
Feedstock suppliers apply for their own stream. CDR developers and biofuel producers put forward one feedstock supplier they buy from, or plan to buy from.
Applications close December 15, 2026. We’ll announce which applications are accepted on December 20, 2026.
Free designations are limited. Ecostrat selects which applications receive one.
Annual monitoring keeps a designation current. Annual monitoring is not part of the free designation.